Vibration Sensor point level measurement - Mononivo MN 4040
Housing | Aluminium IP66, NEMA Type 4/4X |
Certificates | ATEX, IEC-Ex, FM, CSA, INMETRO, EHEDG; also GasEx certificate when flameproof housing is selected. |
Functional Safetz | SIL 2 |
Process Temperature Range | -40°C to +600°C |
Pressure Range | -0,9bar bis +10bar |
Sensitivitz | min. 15g/l - adjustable in 3 Settings |
Process Connection | G1¼" and G1½"; NPT 1¼" and NPT1½"; flange DN100 PN16, other flanges available. |
Process Connection Material | Aluminium or stainless steel 1.4305 (303), 1.4301 (304), 1.4541 (321L) or 1.4404 (316L) |
Extension Material | Stainless Steel 1.4301 (SS304),1.4305 (303) or 1.4404 (316L) |
Mechanical Load | Standard Version 4KN, reinforced version 28KN |
Seal / Bearing | Dust-proof ball-bearing, optional in stainless steel; radial shaft seal in NBR rubber, FPM or PTFE, FPM oder PTFE |
Supply Voltage | AC: 24V / 48V/ 115V/ 230V (50-60Hz); DC: 24V; Universal Voltage 24V DC / 22...230V AC |
Signal Output | Microswitch, relay SPDT contact; PNP Open collector. |
Switchable Signal Output | FSH / FSL with Universal Voltage electronics integrated; with AC electronics as an available option. |
Signal Delay | With Universal Voltage electronics is an integrated adjustable time delay of the signal output |
Fail Safe Alarm | Optional für Universal Electronics; monitoring of motor / transmission / electronics / power failure / line break. |